Maxi Plus Tile and Metal Roof Sarking satisfies BCA specifications and requirements for reflective foil laminates
Complies with the specifications and requirements of AS/NZS 4200:1 for “Pliable building membranes”, which is a manual recognised by the BCA part 3.5 Roof and Cladding
Thickness – less than 1mm
Satisfies health and safety regulations
Satisfies BCA Part 3.7.1 Fire Hazard Properties
Low Flammability Index in accordance with AS 1530.2 <5
Product Information
Maxi Plus Tile and Metal Roof Sarking is manufactured to the highest industry standards.
Roof installation
Up to R1.3 may be added to the insulation system when Maxi Plus Tile & Metal Roof Sarking is installed. During manufacturing, the specialized process bonds together Aluminium Foil to a high-strength reinforcing Polymer Mesh using a flame retardant adhesive. Maxi Plus Tile & Metal Roof sarking is purposely treated blue to reduce the reflective glare problems when installing roofing products.
Usage
In all applications:
External cladding should be installed A.S.A.P
No contact is to be made with wet concrete on mortar
Store in a dry area, weather proofed only after installation
Shrinkage of up to 2% can be expected
In Reflective foil laminate applications:
Use only in accordance with AS/NZ 4200.2 for the “Installation Requirements for Pliable building membranes.
A minimum of 20mm air space is recommended adjacent to the reflective foil face to achieve maximum insulation values.
40mm sag between trusses is recommended when using Maxi Plus Tile and Metal Roof Sarking
For use in enclosed structures
Note: Use in Cold Temperature climates (daytime less than 5Degrees Celsius) requires the roof to be well-ventilated and moist air from within the dwelling to be exhausted into the atmosphere.
Fire Performance
Bushfire attack level
Maxi Plus Tile and Metal Roof Sarking is suitable for BAL 12,5 to FZ as AS3959, section 3.10, except in exposed installations in fire control rooms or fire-isolated exits, in NCC 2019 Volume 1 specification C1.10.
Electrical Safety Warning
This product contains Aluminium Foil which conducts electricity. To avoid electrocution, care should be taken to ensure this product or conductive fasteners used to secure this product do not come into contact or in proximity to electrical wiring during installation or use. This product should not be installed in an existing structure in a horizontal orientation, such as a ceiling or sub-floor application, due to electrical wiring on the framing.
Technical
information
Browse downloadable product files.
1.35m x 30m = 45m2
Recommended Applications and Properties | |
Residential roof insulation | Yes |
Commercial roof insulation | Yes |
Vapour Permeability | 0.011 (ug/Ns) |
Duty | Heavy |
Emittance | Reflective |
Water Control Classification | Water Barrier |
Flammability Index | Low (<5) |
Tensile Strength Machine Direction (kN/M) | Min 12.5 |
Tensile Strength Lateral Direction (kN/M) | Min 7.5 |
Edge Tear Resistance Machine Direction (N) | Min 80 |
Edge Tear Resistance Lateral Direction (N) | Min 80 |
Emittance of Reflective Face | Max 0.05 |
Electrical Conductivity | Conductive |
Maxi Plus Tile and Metal Roof Sarking
Diagram indicating sarking placement