  • Barricade Plus Wall Sarking satisfies BCA specifications and requirements for reflective foil laminates

  • Complies with the specifications and requirements of AS/NZS 4200:1 for “Pliable building membranes”, which is a manual recognised by the BCA part 3.5 Roof and Cladding

  • Thickness – less than 1mm

  • Satisfies health and safety regulations

  • Satisfies BCA Part 3.7.1 Fire Hazard Properties

  • Low Flammability Index in accordance with AS 1530.2 <5

Product Information

Masons Barricade Plus Wall Sarking is manufactured to the highest industry standards.

Wall installation

Up to R1.1 may be added to the wall system when Barricade Plus Wall Sarking is installed as a pliable building membrane behind brick veneer / other claddings with a drained cavity. Our manufacturing team specialized process bonds together Aluminium Foil to a high-strength reinforcing Polymer Mesh using a flame retardant adhesive.

Usage

In all applications:

  • External cladding should be installed A.S.A.P

  • No contact is to be made with wet concrete on mortar

  • Store in a dry area,

  • Shrinkage of up to 2% can be expected

In Reflective foil applications:

  • Use only in accordance with AS/NZ 4200.2 for the “Installation Requirements for Pliable building membranes.

  • A minimum of 20mm air space is recommended adjacent to the reflective foil face to achieve maximum insulation values.

Fire Performance

Bushfire attack level

Barricade Plus Wall Sarking is suitable for BAL 12,5 to FZ as AS3959, section 1.10, except in exposed installations in fire control rooms or fire-isolated exits, in NCC 2019 Volume 1 specification C1.10.

Electrical Safety Warning

This product contains Aluminium Foil which conducts electricity. To avoid electrocution, care should be taken to ensure this product or conductive fasteners used to secure this product do not come into contact or in proximity to electrical wiring during installation or use. This product should not be installed in an existing structure in a horizontal orientation, such as a ceiling or sub-floor application, due to electrical wiring on the framing.

Technical
information

SKUs List
AUBPWS1.35X81
Barricade Plus Wall Sarking

1.35m x 60m = 81m2

AUBPWS1.35X40.5
Barricade Plus Wall Sarking

1.35m x 30m = 40.5m2

AUBPWS1.5X45
Barricade Plus Wall Sarking

1.5m x 30m = 45m2

AUBPWS1.5X90
Barricade Plus Wall Sarking

1.5m x 60m = 90m2

Thermal Performance

Summer

Winter

Fibre Cement Wall Direct Fix (70mm stud)

R, 0.79

R, 0.89

Fibre Cement Wall Batten Fix (70mm stud with 25mm batten)

R, 0.97

R, 1.1

Brick Cavity Wall (90mm stud with 40mm cavity)

R, 1.2

R, 1.3

Electrical Safety Warning

This product contains Aluminium Foil which conducts electricity. To avoid electrocution, care should be taken to ensure this product or conductive fasteners used to secure this product do not come into contact or proximity to electrical wiring during installation or use. This product should not be installed in an existing structure in a horizontal orientation, such as a ceiling or sub-floor application, due to electrical wiring on the framing. 

Recommended Applications and Properties

Vapour Permeability (ug /N.s)

Medium

Vapour Control Membrane Classification (VCM)

0.106

Duty

Class 2

Emittance

Reflective (<0.05)

Water Control Classification

Non Water Barrier

Flammability Index

Low (<5)

Tensile Strength Machine Direction (kN/M)

Min 9.5

Tensile Strength Lateral Direction (kN/M)

Min 6.0

Edge Tear Resistance Machine Direction (N)

Min 6.5

Edge Tear Resistance Lateral Direction (N)

Min 6.5

Water Vapour Transmission Rate (Ng/Ns)

Max 2

Emittance of Reflective Face

Max 0.05

Electrical Conductivity

Conductive

Barricade Plus Wall Sarking

Diagram indicating sarking placement

Get In Touch

Enquire now